Hi,
We have work arounds for this. We will dig deep and come up with a fix but the workaround as of now is as follows:
After upgrading from previous version to 1.2:
- Get the latest SUU dvd. Mount it on the OME server.
- Launch OME and navigate to system update tab
- Click on Select a catalog source
- Provide the path to the catalog in the SUU dvd. The catalog.cab or catalog.xml file can be found in the repository folder of the dvd
- Click on Import now.
- Once the catalog is imported, wait for some time for the compliant and non-compliant list to be populated. Depening on the number of devices, the time for compliance report to be generated may vary from 10-25 minutes.
- Once the report is generated, you will be able to see all your devices under proper groups of compliant and non-compliant systems.
Please let us know if this works for you. We tested and it worked for us.