Re: DRVR_WIN_R317417.exe says it completed succesfully however it did not ( Emulex LightPulse HBA Storport miniport driver 5.212.09)

$
0
0

There are two different issues reported:

Issue 1: OME is unable to deploy the driver package (DUP)

Issue 2: Inventory is not getting refreshed in OME.

Issue1:

OME is able to send and copy the DUP (package) to managed node. However when applying the package it is failing with compatibility check. This is probably an issue w/ silent installation of the package based on the error snippet:

• [03/06/13 22:22:21] User Parameter: logfile changed to: c:\windows\temp\dup.log

[03/06/13 22:22:21] User Parameter: force

[03/06/13 22:22:21] (DupAPI::ValidateCommand): *** DUP Capability check failed

[03/06/13 22:22:21] DUP command not supported by this payload, display user help

[03/06/13 22:22:21] Name of Exit Code: UNKNOWN_OPTION

[03/06/13 22:22:21] Exit Code set to: 11 (0xB)

[03/06/13 22:22:21] Result: FAILURE

Issue 2:

After the update has been applied, it takes time for OMSA (Server Administrator) on the managed node to refresh inventory. You may need to wait 30 minutes and re-attempt to discover/inventory the device. If that does not work, manually delete the device in OME Device tree and re-run discovery+inventory on the discovery range.