Exclude Range

I added a heap of addresses to the exclude range in Discovery and Inventory and now OpenManage Essentials crashes every time i try to open the exlude range, how can i get in the back end and delete all...

View Article


Re: Exclude Range

i figured it out, using sql management studio i deleted all the rows out of the dbo.SubnetExclusion table in the OMEssentials DB

View Article


esxi discovery problem

We have a number of esxi 5.1 hosts.  We've configured them per the documentation, and can discover them with OME 1.1 (patched).  We create a discovery range and use ONLY icmp and ws-man.  It discovers...

View Article

Re: ESXi 5.1 - Becoming Unknown after period of time

I'm having the same problem.  A workaround instead of rebooting the host is to restart OMSA.  Enable SSH on the host then/sbin/services.sh restartThat won't affect running VMs

View Article

Re: ESXi 5.1 - Becoming Unknown after period of time

Restarting wsman service worked for me for a while but it seems like the longer the uptime of the host the more unlikely it becomes that restarting services help at all. in the end i've just disabled...

View Article


Re: Exclude Range

Nice work. Thanks for sharing the info.

View Article

Re: ESXi 5.1 - Becoming Unknown after period of time

VMware has identified an issue affecting VMware ESXi 5.0x and 5.1x where CIM monitoring applications fail to authenticate with “No space left on device” error in /var/log/syslog.log:...

View Article

Re: esxi discovery problem

billmathews,What server model are the ESXi 5.1 running on ? OME only supports WSMAN for discovery of ESXi hosts and other protocols are not supported. However if other protocols other than WSMAN are...

View Article


Re: OMCI 8.1.1 & Dual Monitors

Tim,Probably a OMCI bug. You may get a better response if this issue is posted in general systems management forum. This forum is for OpenManage Essentials (OME), 1xmany console.Thanks,Raj Shresta

View Article


Re: OMCI 8.1.1 & Dual Monitors

Ok.  I can post in that forum.  Does this entry need to be removed?  It's not my intention to crosspost.

View Article

Re: OMCI 8.1.1 & Dual Monitors

No problems. We can keep this post as is... Let us know if you received a response to your query on other forums. If not, we will try to get concerned people to look at it...

View Article

OME and .NET

What version of .NET framework should I insall on WS2008SP2 to make OME happy? Is OME compatible with 4.5?

View Article

Re: OMCI 8.1.1 & Dual Monitors

We (OMCI team) are analysing this issue and shall keep you posted on the development on the issue.

View Article


BMC support on PE 2850

HiI have a Poweredge 2850 with BMC board fitted, running VM ESXi 4.1, and I can access the IPMI data from my Ubuntu Desktop.Is anyone aware of a Linux based GUI that will allow management of the server...

View Article

Re: Can't login to "Managed System Login"

Hello,Check if  the entire OMSA package is installed in the system. If it is, a “Login” page is displayed instead of “Web Server Login” page when you launch OMSA using the desktop icon. Once launched,...

View Article


PowerConnect 2716 in OpenManage essentials

I have a PowerConnect 2716 it is listed in OpenManage essentials as unknown. Is there any way to get OM to recognize the switch? I know according to the support matrix the 2700 series of switches are...

View Article

Re: OME and .NET

Currently shipping OME 1.1 is compatible w/ .NET 3.5. Upcoming OME 1.2 release (tentative July 2013 RTS) will add support for .NET 4.5.OME installer will automatically check if .NET is not found and...

View Article


Re: BMC support on PE 2850

Nigel,If you have a DRAC 4 card, it will allow you to manage the server remotely. I suspect if it is just BMC, it has to be thru' IPMITool (CLI). Another option is to install OpenManage Server...

View Article

Re: PowerConnect 2716 in OpenManage essentials

Unfortunately there is no easy way to make an unsupported device show up as a switch in OME. It will be under Unknown device group.  You can import the MIB for this device using "MIB IMport" utility...

View Article

Re: BMC support on PE 2850

HiThanks for that.I only have the BMC card installed.Do I install Open Manager on the Ubuntu desktop and manage the server remotely ?Nigel 

View Article