Re: WS-Man Discovery

What version of server and iDRAC are you managing ? What is the firmware version on iDRAC ?PERC controller firmware, hard drive firmware etc. are all supported thru' iDRAC. It depends on the catalog...

View Article


Empty report

Hello,I have 90 ESXi 5.0 (PE 11G) monitored by OME 1.1.1 (2008 R2, French localization).All reports are working except "Server components and versions".Is it a known issue ?Thank you

View Article


Re: Empty report

Hi there and thanks for the post.  Let me see if I can look into this.  It may take a few days.Bump the thread next week if you don't hear back from me.Cheers,Rob

View Article

Re: WS-Man Discovery

iDRAC 6 with Firmware version 1.95.00.  After I upgraded to 1.95 I deleted the discovery range and then re-enabled it and it still didn't provide any additional information.  I tried what you said, but...

View Article

Image may be NSFW.
Clik here to view.

Discovery using iDrac or OMSA

Hello, I have the following setup:5x PER710 with ESX 4.1 5x PER720 with ESXi 4.1I want to be able to manage these servers with OME to update as much as possible with the least effort (don't we all...

View Article


Re: Discovery using iDrac or OMSA

I believe with ESXi you can only use the WS-Man discovery method.  You would use the IP of the iDRAC with the iDRAC login creds.

View Article

Re: Discovery using iDrac or OMSA

What are the server models ?For 11G servers (Ex: R710, M610 etc.) and ESX Classic, it is recommended to install OMSA for health monitoring and deploying BIOS/firmware/driver updates. Use SNMP protocol...

View Article

using wsman and recite to promote network boot order

I couldn't find an example for this.This seems to work, but perhaps it could be generalized.Also, I notice NIC 2 doesn't show in the query even if you ask for it, so probably other steps are necessary...

View Article


Re: WS-Man Discovery

Did you try this option as well ?From "Manage -> System updates" page, select "Advanced settings". Select "Enable Downgrades". Wait for 10 mins and select "Disable Downgrades". Check if the PERC...

View Article


Re: WS-Man Discovery

I did test that.  I also reset the DRAC.  The Drac running on 1.80 firmware pulls all firmware information for the system.  The one not working correctly (pulling a limited amount of info) didn't work...

View Article

Re: PowerVault MD3200i showing as unknown

I'm running into the same problem.  The EQUALLOGIC-SMI file is not included in the MIB's file on the EqualLogic website.  When I run the MIB Import Utility 1.1 and try to parse any of the MIB's it...

View Article

Re: Update Failed

After the firmware is updated, it will take approximately 15-20 minutes for inventory to run and pull the new firmware/BIOS version info. If that does not work, delete the device and re-run...

View Article

Re: using wsman and recite to promote network boot order

Hi ssducf, Can you confirm that your system has NIC 2? ...and not just NIC1 Port2.Just run GetBootSourceSettings by itself.thx

View Article


Re: ESXi 5.1 - Becoming Unknown after period of time

Restarting the service does not work for me, I have to reboot the server for it to come back online in OME.

View Article

Re: WS-Man Discovery

Two iDRAC w/ same firmware version are returning different firmare info, correct ? Run this winrm command from OME server on the non-working iDRAC:winrm e cimv2/root/dcim/DCIM_SoftwareIdentity...

View Article


Re: WS-Man Discovery

Output from first command:DCIM_SoftwareIdentity   BuildNumber = 0   Caption = null   ClassificationDescriptions = null   Classifications = 10   CommunicationStatus = null   ComponentID = 20137...

View Article

Re: ESXi 5.1 - Becoming Unknown after period of time

Please call 800-945-3355 and open a ticket. They should be able to provide a quick resolution.

View Article


Re: WS-Man Discovery

CSIOR is disabled which means BIOS is not updating the inventory and iDRAC (LifeCycle Controller) is not pulling the latest inventory. You will probably need to reboot the system. Enter "F2" to enter...

View Article

Re: WS-Man Discovery

Are you sure this is the fix?  I checked the system that is working and it's disabled there as well.Working:DCIM_LCEnumeration   AttributeName = Collect System Inventory on Restart   Caption = null...

View Article

Re: WS-Man Discovery

CSIOR must be enabled on all systems and then system should be rebooted at least once after CSIOR is enabled for the BIOS to refresh inventory. It is possible that the inventory is latest on the other...

View Article